NOTE: CHWMEG Inc. is not affiliated with this facility in any way. 
CHWMEG Inc. does not approve any facilities. 
 
 

Facility Detail

Environmental Management Systems
(No known alias)
CHWMEG Report Number: H777.0


City, State/Prov, Country:Phoenix, Arizona, USA

Member Interest: This facility is currently being tracked by 6 members
(Member interest is not related to how many members use this facility.)

*Location Map:Google Maps

Review Program
(Visit Date):

There are 1 more reviews conducted prior to 2013 not shown.

Description of Services:The EMS facility receives non-PCB dielectric oil for recycling and resale, and also disassembles non-PCB electrical equipment for recovery of scrap metal. The facility will not accept any dielectric oil or electrical equipment having a PCB content of greater than 45 parts per million (ppm). Oil with 2 to 45 ppm PCB content is treated using metallic sodium dispersion to strip the halogens from the PCBs. This is accomplished in a single, heated treatment tank. Following testing to verify PCB removal, oil is pumped via aboveground piping to one of five aboveground storage tanks located in the facility tank farm.

Description Date:2007 Facility Review Program

Facility Location Map:

*CHWMEG, Inc. cannot guarantee the accuracy of the maps. Maps are for informational purposes only. The latitude and longitude for this map are from the most recent CHWMEG facility review.