Veolia ES Technical Solutions
(a.k.a./f.k.a.: Onyx Environmental Services; Shoreland Metals)
CHWMEG Report Number: H402.1


City, State/Prov, Country:Valparaiso, Indiana, USA

Member Interest: This facility is currently being tracked by 4 members
(Member interest is not related to how many members use this facility.)

*Location Map:Google Maps

Review Program
(Visit Date):

There are 2 more reviews conducted prior to 2013 not shown.

Description of Services:The facility accepts tin-plated brass and copper materials (stamped, sheet and roll material). Major onsite processes are stripping of tin plating using caustic solution and subsequent acid and water rinsing to remove a copper oxide which forms after tin plating is removed. Some larger pieces and roll material are shredded prior to processing. Spent sulfuric acid is accepted for acid rinsing. The facility uses an exemption from RCRA regulation for secondary material directly used as a substitute for virgin material—the Indiana Department of Environmental Management (IDEM) concurs with the use of the exemption.

Stripping of tin plating is performed in 6 facility mixers. Stripping is a batch process; residence time is 8-12 hours. Natural gas-fired burners heat mixer contents during the stripping process (180-210 degrees F). After stripping, caustic solution is pumped to one of the stainless steel holding tanks. Tin sludge in the caustic solution cools in the storage tanks, which allows the sludge to precipitate; solution is then pumped through a filter press to concentrate solids, which are later dried in one of the heated mixers to form "tin shot".


Description Date:2007 Facility Review Program

Facility Location Map: